INSTALLING THE APPLIANCE
COMMISSIONING THE APPLIANCE
• Measure and record flue draught
• Check ventilation
• Check no extractor fan, other appliance
or other flue interferes
• With model D, check plumbing circuit
• Complete commissioning card and return
to esse to validate warranty
Flue Connection
The flue pipe used to connect the appliance to the chimney is 6’’ (150mm) in diameter.
A 5-6’’ adaptor is supplied to connect to the flue box of the cooker.
(The flue connection is on the top of the appliance, in the centre at the back.)
Important Installation Notes
1. The installation must allow access for adequate chimney sweeping and flue cleaning.
2. Avoid using bends greater than 45º to the vertical. All flue pipe sections should be as
close to the vertical as possible.
3. All joints in the flue system must be effectively sealed.
4. All flue sockets must face upwards. On completing the installation of the appliance, the
chimney, hearth and walls adjacent to the cooker must conform to local or national
regulations currently in force. In the United Kingdom, the appropriate sections of the
Building Regulations must be conformed to.
5. Air inlet grilles should be positioned so that they are not liable to blockage.
6. An air extraction device shall not be used in the same room as the appliance unless
adequate additional ventilation is provided.
7. A flue cleaning door should be fitted to provide access for cleaning the flue and chimney.
8. Check the appliance for soundness of seals between casting and main components and
that all supplied parts and fittings are correctly fitted.
9. Ensure the appliance is left operational and hand over the operating instructions and
operating tools supplied.
10. Before leaving the installation demonstrate the operation of the appliance to the user.
Explain all controls and flue way access for cleaning.
5